Name: Sectionalizer_pt
Display Field: SUBSTATIONNAME
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Copyright Text:
Default Visibility: true
MaxRecordCount: 1000
Supported Query Formats: JSON, geoJSON, PBF
Min Scale: 6000
Max Scale: 0
Supports Advanced Queries: true
Supports Statistics: true
Has Labels: false
Can Modify Layer: true
Can Scale Symbols: false
Use Standardized Queries: true
Supports Datum Transformation: true
Extent:
XMin: 2865100.12475154
YMin: 421900.08694542904
XMax: 3285100.12514269
YMax: 818900.087315157
Spatial Reference: 32040
(32040)
Drawing Info:
Renderer:
Unique Value Renderer:
Field 1: SUBTYPECD
Field 2: N/A
Field 3: N/A
Field Delimiter: ,
Default Symbol:
Default Label:
UniqueValueInfos:
-
Value: 5
Label: Single Phase Electronic Sectionalizer
Description: N/A
Symbol:
-
Value: 1
Label: Single Phase Hydraulic Sectionalizer
Description: N/A
Symbol:
-
Value: 2
Label: Two Phase Hydraulic Sectionalizer
Description: N/A
Symbol:
-
Value: 4
Label: Three Phase Electronic Sectionalizer
Description: N/A
Symbol:
-
Value: 3
Label: Three Phase Hydraulic Sectionalizer
Description: N/A
Symbol:
Transparency: 0
Labeling Info:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: true
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
Supports Binning LOD: false
Supports Query With LOD Spatial Reference: false
HasZ: false
HasM: false
Has Attachments: false
HTML Popup Type: esriServerHTMLPopupTypeNone
Type ID Field: SubtypeCD
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: OBJECTID
)
-
SHAPE
(
type: esriFieldTypeGeometry, alias: Shape
)
-
BILRATING
(
type: esriFieldTypeString, alias: BILRATING, length: 20
)
-
GROUNDRESISTANCE
(
type: esriFieldTypeString, alias: GROUNDRESISTANCE, length: 20
)
-
INTERRUPTINGMECHANISMTYPE
(
type: esriFieldTypeString, alias: INTERRUPTINGMECHANISMTYPE, length: 20
)
-
INTERRUPTINGMEDIUM
(
type: esriFieldTypeString, alias: InterruptingMedium, length: 5
, Coded Values:
[AIR: Air]
, [OIL: Oil]
, [PUF: Puffer]
, ...3 more...
)
-
SCADACONTROLLED
(
type: esriFieldTypeString, alias: SCADAControlled, length: 5
, Coded Values:
[N: No]
, [Y: Yes]
)
-
SCADAMONITORED
(
type: esriFieldTypeString, alias: SCADAMonitored, length: 5
, Coded Values:
[N: No]
, [Y: Yes]
)
-
MAXCONTINUOUSCURRENT
(
type: esriFieldTypeDouble, alias: MaxContinuousCurrent
, Coded Values:
[50: 50 A]
, [100: 100 A]
, [200: 200 A]
, ...11 more...
)
-
MAXINTERRUPTINGCURRENT
(
type: esriFieldTypeDouble, alias: MaxInterruptingCurrent
, Coded Values:
[2500: 2.5 kA]
, [4000: 4 kA]
, [6000: 6 kA]
, ...13 more...
)
-
MAXOPERATINGVOLTAGE
(
type: esriFieldTypeString, alias: MAXOPERATINGVOLTAGE, length: 20
)
-
NORMALPOSITION_A
(
type: esriFieldTypeString, alias: NormalPosition_A, length: 255
, Coded Values:
[C: C]
, [O: O]
, [UNK: UNK]
)
-
NORMALPOSITION_B
(
type: esriFieldTypeString, alias: NormalPosition_B, length: 255
, Coded Values:
[C: C]
, [O: O]
, [UNK: UNK]
)
-
NORMALPOSITION_C
(
type: esriFieldTypeString, alias: NormalPosition_C, length: 255
, Coded Values:
[C: C]
, [O: O]
, [UNK: UNK]
)
-
PRESENTPOSITION_A
(
type: esriFieldTypeString, alias: PresentPosition_A, length: 255
, Coded Values:
[C: C]
, [O: O]
, [UNK: UNK]
)
-
PRESENTPOSITION_B
(
type: esriFieldTypeString, alias: PresentPosition_B, length: 255
, Coded Values:
[C: C]
, [O: O]
, [UNK: UNK]
)
-
PRESENTPOSITION_C
(
type: esriFieldTypeString, alias: PresentPosition_C, length: 255
, Coded Values:
[C: C]
, [O: O]
, [UNK: UNK]
)
-
COMMENTS
(
type: esriFieldTypeString, alias: COMMENTS, length: 100
)
-
FACILITYID
(
type: esriFieldTypeString, alias: FACILITYID, length: 20
)
-
FACILITYOWNER
(
type: esriFieldTypeString, alias: FACILITYOWNER, length: 10
, Coded Values:
[CNP: CNP]
, [CUSTOMER: CUSTOMER]
)
-
INSTALLATIONDATE
(
type: esriFieldTypeDate, alias: INSTALLATIONDATE, length: 8
)
-
NOMINALVOLTAGE
(
type: esriFieldTypeString, alias: NOMINALVOLTAGE, length: 20
, Coded Values:
[12KV: 12KV]
, [35KV: 35KV]
, [2.3KV: 2.3KV]
, ...1 more...
)
-
PHASEDESIGNATION
(
type: esriFieldTypeString, alias: PhaseDesignation, length: 5
, Coded Values:
[A: A]
, [AB: AB]
, [AC: AC]
, ...20 more...
)
-
SUBTYPECD
(
type: esriFieldTypeInteger, alias: SUBTYPECD
)
-
ANGLE
(
type: esriFieldTypeDouble, alias: ANGLE
)
-
WORKORDERID
(
type: esriFieldTypeString, alias: WORKORDERID, length: 20
)
-
SAP_EQUIP_NUMBER
(
type: esriFieldTypeString, alias: SAP_EQUIP_NUMBER, length: 30
)
-
CIRCUITSECTION
(
type: esriFieldTypeString, alias: CIRCUITSECTION, length: 5
)
-
LINEFUSECD
(
type: esriFieldTypeString, alias: LINEFUSECD, length: 5
)
-
LOCATION
(
type: esriFieldTypeString, alias: LOCATION, length: 48
)
-
GLN
(
type: esriFieldTypeString, alias: GLN, length: 10
)
-
PROPERTYSECTION
(
type: esriFieldTypeString, alias: PROPERTYSECTION, length: 4
, Coded Values:
[BAY: BAYTOWN/CHANNELVIEW SERVICE AREA]
, [BEL: BELLAIRE SERVICE AREA]
, [BRZ: BRAZORIA SERVICE AREA]
, ...14 more...
)
-
SERVICECENTER
(
type: esriFieldTypeString, alias: ServiceCenter, length: 3
, Coded Values:
[BAY: BAY]
, [BEL: BEL]
, [CYP: CYP]
, ...10 more...
)
-
SUBSTATIONNAME
(
type: esriFieldTypeString, alias: SubstationName, length: 6
, Coded Values:
[UNK: UNK]
)
-
CREATION_USER
(
type: esriFieldTypeString, alias: CREATION_USER, length: 50
)
-
DATE_CREATED
(
type: esriFieldTypeDate, alias: DATE_CREATED, length: 8
)
-
DATE_MODIFIED
(
type: esriFieldTypeDate, alias: DATE_MODIFIED, length: 8
)
-
LAST_USER
(
type: esriFieldTypeString, alias: LAST_USER, length: 50
)
-
DATE_POSTED
(
type: esriFieldTypeDate, alias: DATE_POSTED, length: 8
)
-
ANCILLARYROLE
(
type: esriFieldTypeSmallInteger, alias: ANCILLARYROLE
)
-
ENABLED
(
type: esriFieldTypeSmallInteger, alias: ENABLED
, Coded Values:
[0: False]
, [1: True]
)
-
DEVICESTATUS
(
type: esriFieldTypeString, alias: DeviceStatus, length: 6
, Coded Values:
[CLOSED: CLOSED]
, [OPEN: OPEN]
)
-
USECD
(
type: esriFieldTypeString, alias: USECD, length: 3
, Coded Values:
[SEC: Sectionalizer]
, [UNK: UNK]
)
-
REASONCD
(
type: esriFieldTypeString, alias: REASONCD, length: 3
, Coded Values:
[INS: Install Sectionalizer]
, [OTH: OTHER]
)
-
NUMBEROFPHASES
(
type: esriFieldTypeString, alias: NUMBEROFPHASES, length: 3
, Coded Values:
[1: 1]
, [2: 2]
, [3: 3]
, ...1 more...
)
-
COUNTS
(
type: esriFieldTypeSmallInteger, alias: COUNTS
)
-
AMPS
(
type: esriFieldTypeString, alias: AMPS, length: 6
)
-
GLOBALID
(
type: esriFieldTypeGlobalID, alias: GLOBALID, length: 38
)
-
INSTALLED_STATUS
(
type: esriFieldTypeString, alias: INSTALLED_STATUS, length: 15
, Coded Values:
[PRELIMINARY: PRELIMINARY]
, [COMPLETED: COMPLETED]
)
-
LATITUDE
(
type: esriFieldTypeDouble, alias: LATITUDE
)
-
LONGITUDE
(
type: esriFieldTypeDouble, alias: LONGITUDE
)
-
SERVICE_CODE
(
type: esriFieldTypeSmallInteger, alias: SERVICE_CODE
, Coded Values:
[1: Overhead]
, [2: URD]
, [3: UG]
)
-
SAP_FUNCTLOC_ID
(
type: esriFieldTypeString, alias: SAP_FUNCTLOC_ID, length: 30
)
Types:
ID: 3
Name: ThreePhaseHydraulicSectionalizer
Domains:
-
INTERRUPTINGMEDIUM:
Inherited
-
SCADACONTROLLED:
Inherited
-
SCADAMONITORED:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
NORMALPOSITION_A:
Inherited
-
NORMALPOSITION_B:
Inherited
-
NORMALPOSITION_C:
Inherited
-
PRESENTPOSITION_A:
Inherited
-
PRESENTPOSITION_B:
Inherited
-
PRESENTPOSITION_C:
Inherited
-
FACILITYOWNER:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
PROPERTYSECTION:
Inherited
-
SERVICECENTER:
Inherited
-
SUBSTATIONNAME:
Inherited
-
ENABLED:
Inherited
-
DEVICESTATUS:
Inherited
-
USECD:
Inherited
-
REASONCD:
Inherited
-
NUMBEROFPHASES:
Inherited
-
INSTALLED_STATUS:
Inherited
-
SERVICE_CODE:
Inherited
ID: 1
Name: SinglePhaseHydraulicSectionalizer
Domains:
-
INTERRUPTINGMEDIUM:
Inherited
-
SCADACONTROLLED:
Inherited
-
SCADAMONITORED:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
NORMALPOSITION_A:
Inherited
-
NORMALPOSITION_B:
Inherited
-
NORMALPOSITION_C:
Inherited
-
PRESENTPOSITION_A:
Inherited
-
PRESENTPOSITION_B:
Inherited
-
PRESENTPOSITION_C:
Inherited
-
FACILITYOWNER:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
PROPERTYSECTION:
Inherited
-
SERVICECENTER:
Inherited
-
SUBSTATIONNAME:
Inherited
-
ENABLED:
Inherited
-
DEVICESTATUS:
Inherited
-
USECD:
Inherited
-
REASONCD:
Inherited
-
NUMBEROFPHASES:
Inherited
-
INSTALLED_STATUS:
Inherited
-
SERVICE_CODE:
Inherited
ID: 2
Name: TwoPhaseHydraulicSectionalizer
Domains:
-
INTERRUPTINGMEDIUM:
Inherited
-
SCADACONTROLLED:
Inherited
-
SCADAMONITORED:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
NORMALPOSITION_A:
Inherited
-
NORMALPOSITION_B:
Inherited
-
NORMALPOSITION_C:
Inherited
-
PRESENTPOSITION_A:
Inherited
-
PRESENTPOSITION_B:
Inherited
-
PRESENTPOSITION_C:
Inherited
-
FACILITYOWNER:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
PROPERTYSECTION:
Inherited
-
SERVICECENTER:
Inherited
-
SUBSTATIONNAME:
Inherited
-
ENABLED:
Inherited
-
DEVICESTATUS:
Inherited
-
USECD:
Inherited
-
REASONCD:
Inherited
-
NUMBEROFPHASES:
Inherited
-
INSTALLED_STATUS:
Inherited
-
SERVICE_CODE:
Inherited
ID: 4
Name: ThreePhaseElectronicSectionalizer
Domains:
-
INTERRUPTINGMEDIUM:
Inherited
-
SCADACONTROLLED:
Inherited
-
SCADAMONITORED:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
NORMALPOSITION_A:
Inherited
-
NORMALPOSITION_B:
Inherited
-
NORMALPOSITION_C:
Inherited
-
PRESENTPOSITION_A:
Inherited
-
PRESENTPOSITION_B:
Inherited
-
PRESENTPOSITION_C:
Inherited
-
FACILITYOWNER:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
PROPERTYSECTION:
Inherited
-
SERVICECENTER:
Inherited
-
SUBSTATIONNAME:
Inherited
-
ENABLED:
Inherited
-
DEVICESTATUS:
Inherited
-
USECD:
Inherited
-
REASONCD:
Inherited
-
NUMBEROFPHASES:
Inherited
-
INSTALLED_STATUS:
Inherited
-
SERVICE_CODE:
Inherited
ID: 5
Name: Single Phase Electronic Sectionalizer
Domains:
-
INTERRUPTINGMEDIUM:
Inherited
-
SCADACONTROLLED:
Inherited
-
SCADAMONITORED:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
NORMALPOSITION_A:
Inherited
-
NORMALPOSITION_B:
Inherited
-
NORMALPOSITION_C:
Inherited
-
PRESENTPOSITION_A:
Inherited
-
PRESENTPOSITION_B:
Inherited
-
PRESENTPOSITION_C:
Inherited
-
FACILITYOWNER:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
PROPERTYSECTION:
Inherited
-
SERVICECENTER:
Inherited
-
SUBSTATIONNAME:
Inherited
-
ENABLED:
Inherited
-
DEVICESTATUS:
Inherited
-
USECD:
Inherited
-
REASONCD:
Inherited
-
NUMBEROFPHASES:
Inherited
-
COUNTS:
Coded Values:
[2: 2]
, [3: 3]
-
AMPS:
Coded Values:
[15A: 15A]
, [25A: 25A]
, [35A: 35A]
, ...4 more...
-
INSTALLED_STATUS:
Inherited
-
SERVICE_CODE:
Inherited
ID: 6
Name: TwoPhaseElectronicSectionalizer
Domains:
-
INTERRUPTINGMEDIUM:
Inherited
-
SCADACONTROLLED:
Inherited
-
SCADAMONITORED:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXINTERRUPTINGCURRENT:
Inherited
-
NORMALPOSITION_A:
Inherited
-
NORMALPOSITION_B:
Inherited
-
NORMALPOSITION_C:
Inherited
-
PRESENTPOSITION_A:
Inherited
-
PRESENTPOSITION_B:
Inherited
-
PRESENTPOSITION_C:
Inherited
-
FACILITYOWNER:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
PROPERTYSECTION:
Inherited
-
SERVICECENTER:
Inherited
-
SUBSTATIONNAME:
Inherited
-
ENABLED:
Inherited
-
DEVICESTATUS:
Inherited
-
USECD:
Inherited
-
REASONCD:
Inherited
-
NUMBEROFPHASES:
Inherited
-
INSTALLED_STATUS:
Inherited
-
SERVICE_CODE:
Inherited
Supported Operations:
Query
Query Attachments
Query Analytic
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata